Azl logo — azl.com.sa
Materials guide

Polyurethane Spray Foam Insulation: Density, R-Value and Application

Updated: 8 min readBy the Azl technical team

What is spray foam and how does it work?

Spray foam, or spray polyurethane foam (SPF), is a rigid foam formed on site by mixing two liquid components: component A, the isocyanate, and component B, a polyol blend containing catalysts, blowing agent and flame retardants. A plural-component rig pumps both at the temperature, pressure and mix ratio set by the data sheet; they react within seconds, expand and cure into a single layer bonded to the substrate with no joints.

The dual performance comes from the cell structure. In typical roofing foam more than 90% of the cells are closed, according to manufacturer data sheets, trapping a low-conductivity gas that delivers high thermal resistance while blocking liquid water. Because the layer is continuous it wraps corners, pipe penetrations and tank bases without seams, which are exactly the points where leaks usually start in rolled systems.

  • Base foam: rigid roofing foam covered by ASTM D7425 for roofing SPF, while ASTM C1029 covers spray-applied polyurethane thermal insulation in general.
  • Protective topcoat: an elastomeric acrylic, silicone or polyurea coating, or an aggregate layer, because the foam degrades under ultraviolet radiation.
  • Accessories: primer for metal substrates as the manufacturer recommends, and mineral granules broadcast into the coating on maintenance walkways.

Spray foam suits roofs that need both functions and have many penetrations: reinforced concrete roofs of villas and apartment buildings, corrugated metal («shinko») roofs of warehouses and annexes, and joints between the main building and annexes. Service details are on the spray foam insulation page, and roof systems are compared in the roof and building insulation guide.

Where it fits / where it does not
SituationSuitabilityReason
Exposed concrete roof of a villa or buildingVery suitableOne continuous layer that combines both functions and wraps shafts, pipes and tank bases
Metal «shinko» roofSuitableBonds to metal after cleaning and priming, seals fasteners and laps and lowers metal temperature; profile corrugations must be treated first
Joints between building and annexesSuitable with a special detailSprayed over a suitable joint backing with movement monitored; joints with large movement need a separate flexible detail
Roof with heavy foot trafficNot without protectionFoam is not a walking surface; it needs tiles or a protection layer and walkways
Inside a drinking-water tankNot suitableNeeds a system rated for potable-water contact, such as dedicated polyurea or epoxy
Footings and column necks below backfillUsually not suitableBitumen coatings or membranes with a protection board are better below grade
Roof where water ponds for long periodsOnly after slope correctionPonding accelerates deterioration of the protective coating

Advantages and technical properties

  • One seamless layer that reduces weak points at corners and penetrations.
  • High thermal resistance per centimetre compared with most common building insulation materials.
  • Light weight: coated systems add less than half a pound per square foot per inch according to IBHS, i.e. under about 2.4 kg/m² per 2.5 cm.
  • Renewable: the topcoat is typically reapplied every 10–20 years according to IBHS instead of removing the whole system.
Typical values for roofing spray foam (roofing SPF)
PropertyTypical rangeReference
Density40–64 kg/m³ (2.5–4.0 lb/ft³); common products 43–46 kg/m³IBHS; BASF SKYTITE C3-2.8 data sheet
Thermal conductivity kAbout 0.022–0.026 W/m·K (R-5.5 to R-6.5 per inch)IBHS; BASF data sheet about 0.023 W/m·K
Compressive strengthTypically above 40 psi (about 275 kPa)IBHS
Closed-cell contentAbove 90%BASF, per ASTM D6226
Thickness per passAbout 13–38 mm (½–1½ in)BASF and IBHS
Minimum system thickness25 mm (1 in)IBHS
Topcoat dry film thicknessAbout 0.5–1.0 mm (20–40 mil)IBHS
Service surface temperature limits−30 to +107 °CASTM C1029
Typical ranges for comparison; the binding reference is the data sheet of the product actually supplied. More in the guide to reading technical data sheets.

Calculating the R-value at 3 cm and 5 cm

R = d ÷ k

d is thickness in metres and k is thermal conductivity in W/m·K; the result is in m²·K/W. Example: 0.05 ÷ 0.023 = 2.17.

Calculated R-value of the foam layer alone
ThicknessAt k = 0.026 (conservative)At k = 0.023
3 cm1.15 m²·K/W1.30 m²·K/W
5 cm1.92 m²·K/W2.17 m²·K/W
The total resistance of the roof adds the slab and other layers. To compare thicknesses for your building, use the insulation calculator.

Disadvantages and cautions

  • UV degradation: exposed foam deteriorates in sunlight, so the base coat is applied the same day or within 24 hours of spraying according to IBHS.
  • Sensitivity to moisture and wind during spraying: surface moisture weakens adhesion, and wind produces an irregular surface and overspray that can reach cars and neighbours.
  • Operator dependence: mix ratio, temperature and pass thickness determine quality, and errors may only show months later.
  • Not a walking surface: heavy traffic, tank legs and equipment puncture the coating; walkways and pads are required.
  • Site safety: isocyanates require respirators, protective equipment and keeping occupants away from the spray zone. See safety procedures.
  • Fire: foam is an organic, combustible material; it must not be left exposed inside occupied spaces without a thermal barrier as required by the building code.

Standard application steps

  1. 1

    Survey and measurement

    Inspect the slab, slopes and leak locations, measure surface moisture, and record penetrations, joints and drains.

  2. 2

    Surface preparation

    Remove failed insulation, dust and oil, and level low spots. On metal: remove rust, prime and treat corrugations as the manufacturer recommends.

  3. 3

    Masking and rig set-up

    Cover walls, windows and cars, set hose temperature and mix ratio, and choose the product reactivity grade that matches ambient temperature; some products are supplied in summer and winter grades.

  4. 4

    Spraying the passes

    Apply successive passes, each no thicker than the data sheet maximum (typically 13–38 mm), up to 3 or 5 cm, turning the foam up the parapet walls.

  5. 5

    Foam inspection

    Probe thickness at distributed points, check surface texture («orange peel» is acceptable, coarse popcorn texture is not), and cut a small sample to confirm adhesion, then repair the spot.

  6. 6

    Protective topcoat

    A base coat then a top coat in two different colours to confirm full coverage, at a dry thickness of about 0.5–1.0 mm, with granules on walkways.

  7. 7

    Water test and handover

    Flood or spray test depending on the roof, check drains, then hand over a report of thicknesses and products with a written warranty whose term depends on the insulation type and roof condition under the warranty policy.

Climate suitability by Saudi region

Spray foam suitability by region
RegionSuitabilityApplication notes
Central (Riyadh, Qassim)ExcellentHigh roof temperatures and dry air: reflective white topcoat, spray early in the morning with a summer-grade product
Coastal (Jeddah, Dammam, Jazan)Good, with conditionsHumidity and morning dew: check surface moisture and dew point before spraying, and use a coating suited to saline environments
Southern cool (Abha, Khamis Mushait, Al-Baha)Very goodMore rainfall: slopes and drains take priority; avoid spraying before expected rain or in severe cold

For local work: spray foam in Riyadh, spray foam in Dammam, roof insulation in Jeddah and roof insulation in Abha.

Estimated cost

Spray foam typically costs SAR 30–55 per square metre, and a complete roof insulation system (foam with protective coating and preparation) SAR 45–85 per square metre. These ranges are indicative, exclude VAT and are confirmed after a site inspection.

  • Required thickness (3 or 5 cm) and type of protective coating.
  • Roof condition and whether old insulation must be removed.
  • Area, access, and the number of penetrations and joints.

To set the right thickness and system for your roof, request an inspection.

Frequently asked questions

Does spray foam replace waterproofing?

On roofs, yes, if it is applied at a suitable thickness and protected by a continuous topcoat. Closed-cell foam blocks liquid water, and the coating shields it from UV and wear. Foundations, tanks and swimming pools have dedicated waterproofing systems, and foam should not be relied on there as the only barrier.

Which is better for a roof: 3 cm or 5 cm of foam?

Five centimetres gives about 67% more thermal resistance than three, because R-value is directly proportional to thickness. The thicker layer pays off on air-conditioned top floors in hot regions, while 3 cm may be enough for annexes or where other thermal insulation exists. The decision depends on floor use, slab condition and budget.

Can spray foam be applied over old insulation?

Sometimes, if the old insulation is well bonded, dry and sound. Blistered or water-saturated layers and loose tiles must be removed first, because foam only bonds to what lies beneath and does not repair it. The inspection, moisture readings and small test openings in the old insulation decide whether full or partial removal is needed.

What density is right for roofing foam?

Rigid roofing foam is typically between 40 and 64 kg/m³, and many products are supplied at about 43–46 kg/m³. Higher density gives more compressive strength to resist light maintenance traffic. Low-density or open-cell foams are intended for interior insulation and are not suitable as an exposed roof layer.

When does the protective topcoat need renewing?

IBHS notes that coating systems generally need reapplying every 10–20 years; the actual interval depends on coating type and thickness, sun intensity and foot traffic. Periodic inspection for cracking or exposed foam allows recoating before the foam is damaged, which costs far less than re-spraying.

Ask an engineer about your case

Write your question about this topic, and an Azl specialist will reply during working hours.

Topic: Polyurethane Spray Foam Insulation: Density, R-Value and Application

Nothing is stored on this website; your message opens in WhatsApp for you to send to 0544027180. Privacy policy

References and sources

  1. RICOWI Roof Guide: Spray Foam — Insurance Institute for Business & Home Safety (IBHS) · ibhs.org
  2. SKYTITE C3-2.8 Series Technical Data Sheet — BASF · service-partners.com
  3. ASTM C1029 Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation — ASTM International · store.astm.org
  4. SPF standards — Professional Roofing (NRCA) · professionalroofing.net

External links pass through Azl's Consumer Safety Center for checking before leading to other organisations' websites. Citing them does not imply they endorse Azl. Technical values are typical and vary by product; the final reference is the approved product's datasheet and the project design. Editorial policy